Autotransformer reduced voltage starting cabinet is an electrical device used for motor starting. It adopts the principle of autotransformer, reducing the voltage when the motor starts, thereby reducing the starting current, to achieve smooth starting of the motor. This starting cabinet has the advantages of simple structure, reliable performance, convenient operation, etc., and is widely used in various industrial fields.
Safe and Reliable
Equipped with multiple protection functions such as overload, short circuit, undervoltage, etc., effectively protecting the safe operation of motors and equipment.
Wide Application Range
Can be applied to motors of various powers, meeting the needs of different users.
Energy Efficient
The autotransformer reduced voltage starting cabinet can effectively reduce the starting current of the motor, reduce energy consumption, and improve the operating efficiency of the equipment.
Easy Operation
The operation interface of the autotransformer starting cabinet is simple and intuitive, allowing operators to easily get started.
Multiple Voltage Options
380V, 400V, 415V, etc. (can be customized according to user requirements)
Beautiful and Elegant
Adopting modern design, beautiful appearance, suitable for various installation environments
Product Structure

The autotransformer reduced voltage starting cabinet reduces the voltage applied to the motor stator through the autotransformer, thereby reducing the starting current. When the motor starts, the stator winding is connected to the secondary side of the autotransformer, which is in reduced voltage starting state. After the start is completed, the autotransformer is disconnected, the stator winding is connected to rated voltage, and the motor operates at full voltage. Autotransformer reduced voltage starting is one of the starting methods for cage induction motors (also known as asynchronous motors). It has the advantages of compact circuit structure, no limitation by the motor winding connection method, and can select different transformer voltage taps according to the allowable starting current and required starting torque, so it is suitable for motors with larger capacity.
- Press the start button SB2, the coil of time relay KT is energized, the normally open contact of the time relay closes, the time relay starts timing, and at the same time, the coils of KM3 and KM2 are energized and start working, which is the autotransformer reduced voltage starting state. When the timing of the time relay is completed, the delayed opening contact opens, the coils of KM3 and KM2 lose power and stop working, while the normally closed contact closes, the delayed closing contact of the time relay closes, the coil of KM1 is energized, the normally open contact closes, and KM1 starts working. At this point, the autotransformer reduced voltage starting is completed.
- Autotransformer reduced voltage starting is often used to start large-capacity three-phase AC motors. The autotransformer is equipped with taps of 65% and 80% of the line voltage, and the starting current of the motor is 42% and 64% of the full voltage starting current respectively. The starting current and starting torque of the motor decrease proportionally to the square of its terminal voltage. With the same starting current, the motor can obtain greater starting torque.
- Autotransformer reduced voltage starting cabinets are widely used in power, metallurgy, mining, petroleum, chemical, machinery, building materials, textiles, papermaking, food and other industrial fields, as well as urban water supply, sewage treatment, high-rise buildings, airports, docks and other places.
- We always adhere to customer-centric and market-oriented, providing users with cost-effective products and services.
Main Configuration
| Power | Overall Dimensions(mm) | Weight(kg) | AC Contactor Model | AC Contactor Model | AC Contactor Model |
|---|---|---|---|---|---|
| 22kW | 400×290×750 | 42 | CJT1-40A | CJT1-40A | CJT1-20A |
| 30kW | 400×290×750 | 45 | CJ20-63A | CJT1-40A | CJT1-20A |
| 40kW | 470×310×920 | 60 | CJ20-100A | CJ20-63A | CJT1-20A |
| 55kW | 470×310×920 | 73 | CJ20-160A | CJ20-100A | CJT1-40A |
| 75kW | 470×310×920 | 77 | CJ20-160A | CJ20-100A | CJT1-40A |
| 90kW | 550×420×1150 | 115 | CJ20-250A | CJ20-160A | CJ20-63A |
| 115kW | 550×420×1150 | 120 | CJ20-250A | CJ20-160A | CJ20-63A |
| 135kW | 600×480×1280 | 140 | CJ20-400A | CJ20-250A | CJ20-100A |
| 160kW | 600×480×1280 | 160 | CJ20-400A | CJ20-250A | CJ20-100A |
| 190kW | 600×480×1280 | 170 | CJ20-400A | CJ20-250A | CJ20-100A |
| 225kW | 750×550×1550 | 250 | CJ20-630A | CJ20-400A | CJ20-160A |
| 260kW | 750×550×1550 | 260 | CJ20-630A | CJ20-400A | CJ20-160A |
| 320kW | 750×550×1550 | 280 | CJ20-630A | CJ20-400A | CJ20-160A |
| 350kW | 800×550×1650 | 330 | CJ40-800A | CJ20-630A | CJ20-250A |
| 400kW | 800×550×1650 | 350 | CJ40-1000A | CJ20-630A | CJ20-250A |
| 450kW | 800×550×1650 | 380 | CJ40-1000A | CJ40-1000A | CJ20-400A |
| 500kW | 800×550×1650 | 380 | CJ40-1250A | CJ40-1000A | CJ20-400A |
Purchase Notes
- Selection Guide: When purchasing the autotransformer reduced voltage starting cabinet, users should select the appropriate model and specification according to the motor’s power, voltage, current and other parameters.
- Installation and Commissioning: The autotransformer reduced voltage starting cabinet should be installed and commissioned by professional personnel to ensure correct installation and qualified commissioning.
- Use and Maintenance: When using the autotransformer reduced voltage starting cabinet, users should strictly follow the requirements of the product manual for operation and maintenance, and regularly inspect and maintain the equipment to ensure its normal operation.
- Quality Assurance: We provide a one-year quality assurance period. During the quality assurance period, if the product has quality problems, we will provide users with free repair services or replace the product.
The autotransformer reduced voltage starting cabinet can be used with various low-voltage power distribution equipment, such as GGD low-voltage distribution cabinets and GCK low-voltage drawer cabinets, to provide reliable motor starting solutions for industrial and civil power distribution systems. For applications requiring precise speed control, it can also be used with low-voltage frequency inverters or vector variable frequency drives to achieve more efficient motor drive control.
Related Products
You may also like these products
HotSenkuo SK600 High Performance General Vector Inverter
SK600 series general inverter is a high-performance current vector control device designed for industrial automation, supporting asynchronous motor and permanent magnet synchronous motor drive, suitable for textile, paper making, machine tools, fans, pumps and other multi-scenarios. Adopting advanced SVC algorithm and user programmable functions, it provides stable and reliable drive performance.
NewSenkuo SK670 High Performance General Vector Inverter
SK670 series general inverter is a high-performance current vector control device designed for industrial automation, supporting asynchronous motor and permanent magnet synchronous motor drive, suitable for textile, paper making, machine tools, fans, pumps and other multi-scenarios. Adopting advanced SVC algorithm and user programmable functions, it provides stable and reliable drive performance.
HotSenkuo SK320 Series High-Performance Vector Inverter - Precise Speed Control | Energy Saving | Industrial Automation Preferred
Professional Variable Frequency Drive (VFD) manufacturer, providing efficient energy-saving, stable and reliable motor speed control solutions. Suitable for pumps, fans, conveyors, machine tools and other industrial equipment, reducing energy consumption by over 30% and extending equipment life.
NewSenkuo SK800 Series High-Performance Low-Voltage Frequency Inverter - Vector Control Universal Inverter
The Senkuo SK800 series low-voltage frequency inverter is a high-performance vector control device designed for industrial automation, supporting both asynchronous motors and permanent magnet synchronous motors. It is suitable for various scenarios such as textiles, paper making, machine tools, fans, and pumps. Adopting advanced SVC algorithm and user-programmable functions, it provides stable and reliable driving performance.
Need Customized Solutions?
Our technical team will provide professional customized solutions and detailed quotations based on your specific needs